Test-Retests Reliability of Digital Photography in Measuring Quadriceps-Angle and Pelvic Tilt Angle in Healthy Population
Mazhar Ali Bhutto, Azadeh Shadmehr, M. Raza Hadian, Saeed Talebian, Zeb Jehan Rana, Syed Arslan Asad
3365
ABSTRACT
Aim: Capturing body images through digital photography method
for calculation of quadriceps angles and pelvic position in clinical assessment
is an inexpensive method. The aim of this study is to evaluate the reliability
of measuring Q-angle and pelvic tilt angle with digital camera and Microdicom software.
Place and duration: University of Lahore and Tehran University of medical sciences, from
June 2020 to June 2021
Methods: Bilateral
lower limbs of fifteen healthy asymptomatic subjects were considered for
calculations of desired angles. A 13-megapixel camera was used to capture images of quadriceps angle
(q-angle) measurement in an anterior view and for pelvic angle measurement
image in lateral view along with specific landmark markers on the body were
captured. Images were transferred to Microdicom software for calculating desire
angles. Three trails of procedures and Intra-class Correlation Coefficient
(ICC) with 95% Confidence Interval (CI), Munro’s classification for reliability
coefficients were used for the description of degrees. Standard error of
measurement (SEM) was also calculated.
Results: The
Intra-class correlation coefficient values for right side Q- angle was
0.949(0.878-.981) and for left side it was 0.924(0.819-0.972) and <0.005 significant p-value. The ICC results for measuring pelvic title angle in
the right side .990 (.975-.996) and left
legs were .991 (.974-.997). Showing that the results were highly
reliable and significant (p<0.005).
Conclusions: The q-angle
and pelvic angle measured with digital image have excellent consistency and
reliability.
Keywords: angle,
asymptomatic, Images, pelvic, quadriceps,